Air Velocity (Vane Anemometer Probe) :
0.4 to 30 m/s, ±3% +0.2 m/s ; 79 to 5906 ft/min, ±3% +40 ft/min; 1.4 to 108 km/h, ±3% +0.8 km/h; 0.9 to 67.2 mph, ±3% +0.4 mph; 0.8 to 58.3 knots, ±3% +0.4 knots
Air Flow :
0 to 999900 CMM (0 to 999900 CFM)
Air Temperature :
10 to 30°C (50 to 86°F), ±1°C (1.8°F); -30 to 9.9°C (-22 to 50°F) and 31 to 60°C (88 to 140°F), ±2°C (3.6°F)
Product thumb
FLIR EM54
HVAC/R Environmental Meter

Specifications

  • Air Velocity (Vane Anemometer Probe) :  0.4 to 30 m/s, ±3% +0.2 m/s ; 79 to 5906 ft/min, ±3% +40 ft/min; 1.4 to 108 km/h, ±3% +0.8 km/h; 0.9 to 67.2 mph, ±3% +0.4 mph; 0.8 to 58.3 knots, ±3% +0.4 knots
  • Air Flow :  0 to 999900 CMM (0 to 999900 CFM)
  • Air Temperature :  10 to 30°C (50 to 86°F), ±1°C (1.8°F); -30 to 9.9°C (-22 to 50°F) and 31 to 60°C (88 to 140°F), ±2°C (3.6°F)
  • Relative Humidity :  5% to 98% ±3.5%
  • Dew Point :  -30 to 60°C (-22 to 140°F), ±3°C (4.8°F)
  • Wet Bulb (Calculated) :  -30 to 50°C (-22 to 122°F), ±3°C (4.8°F)

Imaging & Optical

  • Display Type :  Backlit, multifunction LCD

General

  • Air Flow :  0 to 999900 CMM (0 to 999900 CFM)
  • Anemometer Body Length :  150 mm (5.9 in)
  • Anemometer Cable Length :  950 mm (37.4 in)
  • Anemometer Vane Diameter :  70 mm (2.8 in)
  • Dimensions (L x W x H) :  275 × 65 × 45 mm (10.8 × 2.6 × 1.8 in)
  • Housing material :  Impact-resistant plastic
  • Includes :  283.9 g (10 oz) with battery installed, no external probes
  • Weight :  283.9 g (10 oz) with battery installed, no external probes

Measurement & Analysis

  • Air Temperature :  10 to 30°C (50 to 86°F), ±1°C (1.8°F); -30 to 9.9°C (-22 to 50°F) and 31 to 60°C (88 to 140°F), ±2°C (3.6°F)
  • Air Velocity (Vane Anemometer Probe) :  0.4 to 30 m/s, ±3% +0.2 m/s ; 79 to 5906 ft/min, ±3% +40 ft/min; 1.4 to 108 km/h, ±3% +0.8 km/h; 0.9 to 67.2 mph, ±3% +0.4 mph; 0.8 to 58.3 knots, ±3% +0.4 knots
  • Dew Point :  -30 to 60°C (-22 to 140°F), ±3°C (4.8°F)
  • Relative Humidity :  5% to 98% ±3.5%
  • Temperature Type K thermocouple :  -99.9 to 99.9°C (-148 to 212°F), ±1.5% +1°C (1.8°F); 100 to 1372°C (212 to 2502°F), ±1.5% +2°C (3.6°F)
  • Wet Bulb (Calculated) :  -30 to 50°C (-22 to 122°F), ±3°C (4.8°F)

Power

  • Auto Power Off (APO) :  Configurable from 5 to 60 min in 8 increments
  • Battery life :  120 hours typical
  • Battery status indicator :  Low battery indication
  • Battery type :  1x 9 V

Environmental & Certifications

  • Certifications :  CE, RCM
  • Drop test :  1 m (3.3 ft), not including removeable probes
  • Operating Temperature :  0 to 50°C (32 to 122°F)
  • Storage Temperature Range :  -10 to 60°C (14 to 140°F)
  • Warranty :  Limited 3 years

Product thumb
FLIR EM54
HVAC/R Environmental Meter

The FLIR EM54 is ideal for inspecting and troubleshooting HVAC/R ducting systems within residential, commercial, and industrial facilities. This meter can help you verify that duct inlets and outlets have the specified volumetric flow – a prerequisite to an efficient functional system. Featuring humidity, wet bulb, and dew point functions, the EM54 can measure deviations from proper relative humidity levels. Plus, the included Type-K contact temperature probe is useful to check electric motors and thermal equipment components for proper operating temperatures.