FLIR CM85-2
True RMS Power Clamp Meter (Wireless)
FLIR CM85-2
True RMS Power Clamp Meter (Wireless)
Featured Information
Jaw Opening :
45 mm (1.77 in)
AC Current :
99.99 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits) 999.9 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits)
Safety Category :
CAT IV-600 V, CAT III-1000 V
.png)
FLIR CM85-2
True RMS Power Clamp Meter (Wireless)
Specifications
- Jaw Opening : 45 mm (1.77 in)
- AC Current : 99.99 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits) 999.9 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits)
- Safety Category : CAT IV-600 V, CAT III-1000 V
- Measuring Rate : 3 times per second
- Peak Hold : ACV: 140.0 V, ±(3.0% + 15 digits) 1400 V, ±(3.0% + 15 digits) ACA: 140.0 A, ±(3.5% + 15 digits) 1400 A, ±(3.5% + 15 digits)
- Power Factor : -1.00 to 0.00 to +1.00, ±3° ±1 digit
- Recording : Data recording available via METERLiNK App
- Resistance : 999.9 Ω, ±(1.0% + 5 digits) 9.999 kΩ, ±(1.0% + 3 digits) 99.99 kΩ, ±(1.0% + 3 digits)
- VFD : ACV: 99.99 V, 50–60 Hz ±(1% + 5 digits) 999.9 V, 50–60 Hz ±(1% + 5 digits) ACA: 99.99 A, 50–60 Hz ±(2% + 5 digits) 999.9 A, 50–60 Hz ±(2% + 5 digits)
- Watts : DC: 9.999 kW (10 V, 5 A min), ±(3% + 0.05 kW) 99.99 kW (10 V, 5 A min), ±(3% + 0.5 kW) 999.9 kW (10 V, 5 A min), ±(3% + 10 digits) AC: 9.999 kW (10 V, 5 A min), ±(3% + 10 digits) 99.99 kW (10 V, 5 A min), ±(3% + 10 digits) 999.9 kW (10 V, 5 A min), ±(3% + 10 digits)
Power
- Auto Power Off : Approximately 30 minutes
- Battery life : 50 hours with alkaline batteries (backlight, work light, and Bluetooth are off)
- Power Requirements : 6 × 1.5 V AAA alkaline batteries
Environmental & Certifications
- Certifications : UL, CE, FCC, IC, UKCA, CSAUS
- Drop test : 1.2 m (4 ft)
- EMC : FCC: 47 CFR Part 15 Subpart B CE: EN IEC 61326-1:2021 EN IEC 61326-2-2:2021 EN 301 489-1 V2.2.3 (2019-11) EN 301 489-17 V3.2.4 (2020-09) RF: ETSI EN 300 328 V2.2.2 EN 62479:2010 EN 50663:2017
- Operating Temp & Humidity : 0°C to 10°C (32°F to 50°F) (non‐condensing) 10°C to 30°C (50°F to 86°F) (≤80% RH) 30°C to 40°C (86°F to 104°F) (≤75% RH) 40 to 50°C (104°F to 122°F) (≤45% RH)
- Safety Category : CAT IV-600 V, CAT III-1000 V
- Safety Standards : IEC 61010-1:2010, IEC 61010-2-032:2012, IEC 61010-2-033:2012
- Shock & Vibration : Random vibration per MIL‐PRF‐28800F Class 2 (5 Hz to 55 Hz, 3 g maximum)
- Storage temperature and relative humidity [RH] : -10°C to 50°C (14°F to 122°F). 0–80% RH (batteries not fitted)
- Temperature Coefficient : 0.2 × (specified accuracy)/°C, <18°C, >28°C
- Warranty : Limited Lifetime Warranty www.flir.com/testwarranty
Measurement & Analysis
- AC Current : 99.99 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits) 999.9 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits)
- AC Voltage : 99.99 V, 50–500 Hz ±(1.0% + 5 digits) 999.9 V, 50–500 Hz ±(1.0% + 5 digits)
- Capacitance : 3.999 μF, ±(1.9% + 8 digits) 39.99 μF, ±(1.9% + 8 digits) 399.9 μF, ±(1.9% + 8 digits) 3.999 mF, ±(1.9% + 8 digits)
- Continuity : 999.9 Ω, ±(1.0% + 5 digits)
- DC Current : 99.99 A, ±(2% + 0.5 A) 999.9 A, ±(2% + 5 digits)
- DC Voltage : 99.99 V, ±(0.7% + 2 digits) 999.9 V, ±(0.7% + 2 digits)
- Diode : 0.40 to 0.80 V, ±0.1 V
- Frequency : 20.00 to 99.99 Hz, ±(0.5% + 3 digits) 20.0 to 999.9 Hz, ±(0.5% + 3 digits) 0.020 to 9.999 kHz, ±(0.5% + 3 digits)
- Harmonics : Total harmonic distortion ACA/ACV: 99.9%, ±(3.0% + 10 digits) Harmonic distortion: H01–H12 99.9%, ±(5% + 10 digits) Harmonic distortion: H13–H25 99.9%, ±(10% + 10 digits)
- Inrush Current : ACA: 99.99 A, ±(3% + 0.3 A) 999.9 A, ±(3% + 5 digits)
Communication & Data Storage
- Bluetooth range max : 10 m (32 ft)
General
- Dimensions (L x W x H) : 276 mm × 101 mm × 50 mm (10.87 in × 3.98 in × 1.97 in)
- Jaw Opening : 45 mm (1.77 in)
- Weight : Total weight including batteries: 0.65 kg (1.43 lb)
- Worklights : Yes
.png)
FLIR CM85-2
True RMS Power Clamp Meter (Wireless)
The FLIR CM85-2 is an industrial power clamp meter with advanced power analysis and variable frequency drive (VFD) filtering functions required by electrical troubleshooters for full-scale equipment. Accurately analyze voltage in complex machinery by including harmonics, inrush, current, and phase rotation testing with a wide AC/DC voltage range and base accuracy of ±1%. Stream live data in real time from the CM85-2 to your mobile device over Bluetooth®. Using the METERLiNK® app, you can compare log files, create alarm thresholds, visualize trends, and create reports to share with team members.